Menu

Full power Emergency Dimmable LED Panel Light

Giá: Liên hệ

Emergency Dimmable LED Panel Light

(1) With the high temperature resistance Ni-MH rechargeable battery.
(2) Applicable to 0W-50W of LED panel light, lamp and other emergency lighting.
(3) Applicable to the led light with a external drive power LED Emergency Panel Light.
(4) When the emergency ,it is about the half power of the light ,it is energy-saving, and easy for the user to save costs.
(5) International electrical wiring ,it is half of the power when emergency ,and three kinds of color indicator light.
(6) when the AC Input is work properly , the inverter allows emergency lighting battery pack in charging \ standby state ; when suffer the earthquake, hit, explosions and other accidents or other emergencies caused by sudden Interrupted of AC , then the inverter converts DC battery pack emergency lighting power supply to continue to ensure that lighting and safety. Green, red, yellow and three LED lamp beads show the normal main power, charging, Fault condition, the battery charge saturation, automatically into maintenance charge status, compensation self-discharge, maintain battery performance and service life. Match different capacity battery, can be achieved 1-5 hours of emergency lighting time, to meet the needs of different occasions. Can be used at temperatures -25 to + 60.
(7) Strictly fellow the wiring diagram to connect the wire ,and please don’t open the cover without professional worker.
(8) User need to check the inverter discharge conditions at the regular intervals before cut off the power .and then turn on the light with the battery.

VMEC hiện là đại diện độc quyền tại Việt Nam nhập khẩu, cung cấp và phân phối sản phẩm LVT LED.

Thông tin chi tiết

TECHNICAL SPECIFICATIONS

  • Model of Power Supply:The inverter and 12VNi-MH rechargeable battery
  • Input Voltage:AC170~260V ±30V /50~60HZ DC25~90V
  • Output Voltage:DC 20~60V
  • Power:0~54W
  • Battery capacity:Customized
  • Charging time:>32h
  • The power scope:0-54W don't support more than 2 emergency light for lighting.
  • Emergency time:>1.5hours, or according to our clients' requirement to design the emergency time.
  • Charging protected the voltage:15.0V
  • Discharging terminated the voltage: 10.0V
  • Display settings:Green Light--main line, Red Light--charging, Yellow Light--trouble
  • Environmental temperature:20~60℃、65+20% RH
  • Battery:12V
  • Charging current:100~200mA
  • Dimension:350x75x57mm(Size will change according to diffeent powers, any questions, please contact us)
  • emergency mode:Full power
  • Warranty: 2 years

RODUCT SPECIFICATION OF PANEL LIGHT

※ According to the different permutation and combination way to assemble the several D5000mAh1.2V Ni-MH battery together; 
※ The customer should charge the battery with the little current for a long time ,because the Ni-MH battery is with the better charging ,discharging ,resistance to low and high temperature ,lifetime , safety and storage ,it is the first choice for the emergency battery; 
※ Because Ni-MH battery is with the bigger capacity , smooth discharge ,wide universality,and less heat ,it is one of the most popular green environmental protection battery;
※ It will be better for the battery when you charge the battery before it is fully discharge; 
※ After the group of Ni-MH 12.0VD5000mAh fully discharge , The customer should charge the battery for more than 48 hours to ensure the battery with the full power and the inverter is of the function of charging protection .It can ensure the less damage to the battery when charge .After the battery was fully charging ,it should charge the battery with the little current to supply the self-discharge of the battery; 
※ Driver and battery can resist the high temperature ,it can work in -20~60 ℃; 
※ Taking the application into the consideration ,it would be better for the user to check the battery at regular intervals ,and it must change the battery after 3 years;
※ The warranty of the battery material is 2 years ,it can meet the standard of international IEC61951-2003 ,the cycle lifetime is over 500 period LED Emergency Panel Light;
※ Please pay attention the safety when use the battery .Please not disassemble the battery or short the circuit or put the battery into the water or fire to avoid the peril.

ELECTRICAL CONNECTION

Emergency panel light Electrical Connection

LED EMERGENCY POWER SUPPLY INSTALLATION INSTRUCTION

1: accordance with writing diagram to connect the circuit in strict. The following lines are connected to each port;
Terminal function diagram

Terminal 1—— connect FireWire L+ LED external drive firewire input. This line can set a wall switch S. The wall switch only controls the main power, no function on emergency lighting.
Terminal 2—— connect the zero line N+LED external drive zero line input.
Terminal 3——one line connect with the other side of wall switch S, enter the fire wire 1port; one line connect with LED drive’s firewire.
Terminal 4—— connect LED drive’s output positive.
Terminal 5—— connect light source’s negative +light source external drive’s output negative.
Terminal 6——light positive Diagram wiring, all lines and accessories connected to complete before connecting to the mains test, non-live working.


2: Emergency power supply can not no-load, whether it is testing emergency lighting function or testing the inverter charging function, must be process under load light source;
3: Main power line: fire line L and zero line N, connect to main power line directly, these two lines are forbidden to connect the switch;
4: Not control by switch S after the light source start emergency lighting;
5: Green indicator: main power; Red indicator: charging; yellow: falut;
6: no indicator works in emergency status except emergency lighting;

MAINTENANCE

Emergency movement is the core device which controls the battery charge or discharge and start the lighting when under emergency must ensure the wiring is correct. After under normal use, need to discharge once every three months for battery conservation and extend the battery life. Emergency lighting power installed and put into use, need to regularly check, maintain, examine and repair when discover the abnormal condition, or inform the supplier to deal with LED Emergency Panel Light.

EMERGENCY POWER LED PANEL LIGHT DESCRIPTION

Facroty direct saleemergency led panel light, which is composed of the led panel light and the no harmful Ni-MH rechargeable battery, it can light for 2-3 hours when there is a power failure.

Các sản phẩm khác

0904 583 593